Description | Metric | Imperial | |
---|---|---|---|
1 | Model name | agriGaLF 120 | agriGaLF 120 |
2 | Model number | FZ1G-120 | FZ1G-120 |
Liquid | Metric | Imperial | |
3 | Flow / minute | 200 Liter | 53 Gallon |
4 | Flow / hour | 12 M3 | 424 CF |
5 | water temperature minimum | 0 ℃ | 32 ℉ |
6 | water temperature maximum | 45 ℃ | 113 ℉ |
7 | Strainer availability and size | Yes 400 μm | Yes 400 μm |
8 | Recommended inlet filter(s) | Medium pump inlet filter series | Medium pump inlet filter series |
Ambient | Metric | Imperial | |
9 | Ambient temperature minimum | 0 ℃ | 32 ℉ |
10 | Ambient temperature maximum | 40 ℃ | 104 ℉ |
11 | Relative humidity minimum | 45 % | 45 % |
12 | Relative humidity maximum | 85 % | 85 % |
Gas | Metric | Imperial | |
13 | Flow / minute | 8.0 Liter | 2.1 Gallon |
14 | Flow / hour | 480 Liter | 127 Gallon |
15 | Pressure | 130 kPa | 19 PSI |
16 | Gas quality | Do not use corrosive gases. Use of Oxygen, Carbon Dioxide, Nitrogen or Ambient Air is allowed. | Do not use corrosive gases. Use of Oxygen, Carbon Dioxide, Nitrogen or Ambient Air is allowed. |
17 | Gas remark | Gas intake time 3 seconds / 2 minutes. | Gas intake time 3 seconds / 2 minutes. |
Electrical | Metric | Imperial | |
18 | Unit phase Ø voltage | 3 Ø 200 ~ 240 VAC | 3 Ø 200 ~ 240 VAC |
19 | Unit power consumption | 3000 watts | 3000 watts |